>>32
â Effect of Electromagnetic Field on Serum Biochemical Parameters in Steelworkers
ééŒåŽåè
ã®è¡æž
çååŠçãã©ã¡ãŒã¿ã«ãããé»ç£çã®åœ±é¿
ã Boguslaw KULA, A ndrzej Sobczak, Rozalia Grablowska-Bochenek and Danuta Piskorska/
J Occup Health 1999;41:177-180
èŠæš
ç 究ã®ç®çã¯ãé»ç£èªå°å ç±åšã«ãã£ãŠçæãããé»ç£å ŽïŒ20 V/mã®é»ç匷床ãš2 A/mã®ç£ç匷床ïŒã«æããã
ééŒåŽåè
ã®è¡æž
ã®ããã€ãã®çååŠçãã©ã¡ãŒã¿ãŒãè©äŸ¡ããããšã§ãããç·èçœè³ªãβ-ããã³Î³-ã°ãããª
ã³ã®ã¬ãã«ãããã³Î³-ã°ã«ã¿ãã«ãã©ã³ã¹ãããããŒãŒ(E.C.2.3.2.2)ãšãªã³ãŽé
žè±æ°ŽçŽ é
µçŽ (E.C.1.1.1.37)ã®
掻æ§ã«ææãªæžå°ãèŠãããŸãããã¢ã¹ãã©ã®ã³é
žã¢ãããã©ã³ã¹ãã§ã©ãŒãŒ(E.C.2.6.1.1)ã®æŽ»æ§ã¯æžå°ããŸã
ãããã¢ã©ãã³ã¢ãããã©ã³ã¹ãã§ã©ãŒãŒ(E.C.2.6.1.2)ã®æŽ»æ§ã¯å€åããŸããã§ãããç·è質ãã³ã¬ã¹ãããŒã«
ãããªã°ãªã»ãªãããã¬Î²ãªãèçœè³ªã¯æžå°ããŸããããαãªãèçœè³ªã¯å¢å ããŸããã
ç 究ãããçååŠçãã©ã¡ãŒã¿ã®æãé¡èãªå€åã¯ãé»ç£å Žãžã®æé²ãæãé·ãåŽåè
ã«èŠãããŸããã